Optical fiber cable 12 core LS Korea
LS optical fiber cables are produced in Korea. The following specifications cover the general requirements for optical fibers. The 12-core multimode cable has a sheath, which is usually PE or LSZH. Blinds are color coded. The structure of the cable is in the form of a central loose tube. It has power member, rapcord and final coating. These cables are used in channels.
Multimode optical fiber cable
The structure of Korea LS 12-core optical fiber cable is according to the following table:
Number of optical fiber cables: 12 (maximum 24)
Loose tube buffer: PBT (polybutylene terephthalate)
Filling the compound in loose tube: thixotropic gel compound
Resistant member: glass threads
Ripcord: A ripcord
Outer Jacket: Material: Black PE or Black LSZH
Outer jacket: thickness: nominal 1.0mm
Identification of buffer tube and loose tube
The color code of individual fibers is according to table 5 below:
Blue
orange
Green
Brown
Gray
white
Red
Black
yellow
Purple
red
blue green
Blue tape / single ring
Orange tape / single ring
Green tape / single ring
Brown tape / single ring
Gray tape / single ring
White tape / single ring
Red tape / single ring
normal
Yellow tape / single ring
Purple ribbon / single ring
Red tape / single ring
Blue tape / single ring
Temperature range of multimode fiber optic cable
For cables covered by this specification, the following temperature ranges apply:
– Performance: -20°C to +70°C
– Installation: -10°C to +60°C
– Storage/Transportation: -20°C to +70°C
Mechanical and environmental performance of multimode optical fiber cable
The mechanical and environmental performance of Korea’s 12-core LS optical fiber cable is according to the table below. Unless otherwise specified, all attenuation measurements for this section shall be made at 1550nm (SMF) and at 1300nm (MMF) in the table below.
Tensile loading test and bending test:
# Test method: TIA / EIA-455-33A
– Mandel diameter: 30D (D = cable diameter
– Installation tensile load: 1200 newtons for 1 hour
– Residual tensile load: 600N for 10 minutes
# Acceptance criteria
– Flexibility of fibers: 0.6 lb to install tensile load
– Damping increase: 10 0.10 dB (SMF)
20 0.20 dB (MMF)
for residual tensile load
Compressive strength test:
# Test method: TIA / EIA-455-41A
– Short-term load: 2200 N / 10cm for 1 minute
– Long-term load: 1100 N / 10cm for 10 minutes
# Acceptance criteria
– Damping increase: 10 0.10 dB (SMF)
20 0.20 dB (MMF)
After completing the test
– Without cracking the jacket and breaking the fiber
Repeat impact test:
# Test method: TIA / EIA-455-25C
– Impact height: 150 mm
– Effective mass: 3 kg
– Number of impact cycles: 2 cycles at 3 different points
# Acceptance criteria
– Damping increase: 10 0.10 dB (SMF)
20 0.20 dB (MMF)
After completing the test
– Without cracking the jacket and breaking the fiber
Annular flexibility test:
# Test method: TIA / EIA-455-104A
– Plate diameter: 20D (D = cable diameter)
– Number of flexibility cycles: 25 cycles
– Flexible speed: 30 cycles per minute
# Acceptance criteria
– Damping increase: 10 0.10 dB (SMF)
20 0.20 dB (MMF)
After completing the test
– Without cracking the jacket and breaking the fiber
Cable twist test:
# Test method: TIA / EIA-455-85A
– Twisted cable length: 2 meters
– Number of twisting cycles: 10 cycles
– Rotation angle: ± 180 degrees
# Acceptance criteria
– Damping increase: 10 0.10 dB (SMF)
20 0.20 dB (MMF)
After completing the test
– Without cracking the jacket and breaking the fiber
Temperature cycle test:
# Test method: TIA / EIA-455-3A
– Temperature cycling program
: 23 ° C® -20 ° C® 70 ° C® -20 ° C® 70 ° C® 23 ° C
– Soaking time at any temperature: 8 hours
# Acceptance criteria
– Damping increase: 15 0.15 dB/km (SMF)
30 0.30 dB/km (MMF)
Water penetration test:
# Test method: TIA / EIA-455-82B
– Sample length: 3 meters
– Pressure head height: 1 meter
– Exam time: 24 hours
# Acceptance criteria
– No leakage from open cable ends
Flammability test (only LSZH jacket cable):
# Exam method and acceptance criteria
The cable must conform to IEC 332-1.
10.15.18.103 / 2014.03.20 16:15 / 20090210
LS cable
Cable marking
The jacket should be marked at one meter intervals with the following information. other
Marking is also available upon customer request.
1) Cable type (SJNA-CT”)
2) Fiber type and number (for example, “12 x G652D”)
3) Manufacturer’s name
4) year and month of manufacture
5) length mark
Example 1) for a 12 fiber cable
Fiber optic cable specifications
The diameter, weight and minimum bending radius are as follows:
Optical fiber number: 12
Fiber optic cable diameter: 6.3 mm
Approximate cable weight: 36 kg
Minimum bending radius (mm): in loaded mode: 126, in normal mode: 63
The above information is related to Korea’s 12-core LS optical fiber cable product in the optical fiber bank, which you can make your choice with the help of its specifications.